Caption Data Limited

 

Remote Data Logging - Online & Real-Time

Caption Data Ltd. - RDLPower - Remote Data Logging - On Line & Real Time

 

RDLPower

High Accuracy Remote Power Monitoring System

RDLPower - internet enabled power monitor/logger

Take high accuracy measurments remotely and view reading through your internet browser

  • Low cost GPRS based system designed for power usage and quality monitoring/recording.
  • Remote currents, Voltages, frequency, reactive and apparent power, power factor, energy (kWh, Kvar) and more.
  • Uses standard current clamps and Volatge probes.
  • Compact and simple to install.
  • Automatic interface to web bureau - No complicated set up!
  • Full archiving of data on secure web bureau.
  • Send alarms on 'user definable' parameters.
  • Administer virtually unlimited remote sites via one user.
  • Add extra users/customers to the system to give them real time access to the information.
  • Use standard interent browsers - No need to Install, Maintain and update client based software.

The RDLPower system will have the option of providing all of the parameters listed below and will present them to the web bureau.

 Measurement in real effective values (TRMS) of:

bullet Currents per phase and instantaneous neutral, average and maximum values over a programmable period.
bullet Phase-to-neutral and phase-to-phase voltages, instataneous, average and maximum over a programmable period.
bullet Frequency, instantaneous, average and maximum over a programmable period.
bullet Active power on 4 quadrants (±) per phase and total in instantaneous, average and maximum values over a programmable period.
bullet Reactive power on 4 quadrants (±) per phase and total in instantaneous, average and maximum values over a programmable period.
bullet Apparent power per phase and total in instantaneous, Active power on 4 quadrants (±) per phase and total in instantaneous, average and maximum values over a programmable period.
bullet Power Factor (PF) per phase and total with inductive or capacitive indication.
bullet Harmonic distortion rate (THD) up to 51 on phase-to-neutral and phase-to-phase voltages and currents (THD 3U, THD 3V, THD 3I, THD In).
 
 
Metering:
bullet Active power meter on 4 quadrants.
bullet Reactive power meter on 4 quadrants.
bullet Apparent power meter.
bullet Programmable hour run meter.
 
 
Additional Options Available:
bullet Ambient temperature or component surface temperature.
bullet Ambient Humidity
bullet Lighting levels.
 

Full Information In PDF Format (927KB)

Bookmark and Share
Copyright © Caption Data Limited 2011. All Rights Reserved
Tel: 01905 754078 Fax: 01905 759640 Email: enquiries@assetmonitoring.eu